BASE: CAIRO WEST    POPULATION:                 AS OF DATE:      24 SEP 90     
COUNTRY  EGYPT            CURRENT:  
                                              PROJECT:  1000     POC:   [(b)(2)]
______________________________________________________________________
                                                         SERVICES

PRIME RIBS:                                                         FEEDING STATUS:
CURRENT:  0                                                        CONTRACT?:  Y 
PROJECTED: 34                                                    FALCON KITS:  ONE 1 9-1 KITCH SOURCED 
                                                                               MKT'S:      0
                                                                               MRE'S:  WILL NEED MRE'S 
                                                                               B-RATS:  WILL NEED B-RATIONS

BILLETING STATUS:                                           LAUNDRY STATUS:
CONTRACTED AVAIL/USED:  1200+/2              CONTRACT AVAIL/USED:  YES
ON-BASE AVAIL/USED:  0/0                               FIELD AVAIL/USED:  2 SOURCED
TENT SPACE AVAIL/USED:  TENT CITY SOURCED 

MORTUARY STATUS:                                         TAC FIELD EXCHANGE STATUS:  WILL
QTY XFER CASES:   5                                                                                         NEED ONE             
QTY BAGS:  1 1/2 CS 
_____________________________________________________________________________
                                                           ENGINEERING 

PRIME BEEF: 				           WATER STATUS:  BOTTLED DRINKING 
CURRENT  100                                                      QTY/DAY LOCAL:  UNLIMITED
PROJECTED:  100(50 OFFUTT C+_)	           DIST SYS STATUS:  NOT INSTALLED 
                                                                               TREATMENT STATUS:  ONLY CHLOR REQ'D 
SANITARY STATUS: Y                                        ROWPU STATUS: NOT REQ'D
LOCAL SYS:  NONE                                             ERD STATUS:  NOT REQ'D
FIELD SYS:  NEED FIELD UNITS                        STORAGE CAPACITY:  NEED BLADDER

SHOWER/SHAVE STATUS:  3                              POWER STATUS:
LOCAL SYS AVAIL/QTY:   0                                COMMERCIAL AVAIL/CAP:  NEED 		
									     GENERATORS 
FIELD SYS AVAIL/QTY:  3                                   FIELD AVAIL/CAP:  NINE
                                                                                DISTRIBUTION SYS CAP:  NOT INSTALLED 
                                                                                GENERATOR QTY/CAP:  NONE 

ATH HOSP STATUS:  2 ATC 
WASTE MGMT SYS:  TO BE DONE BY               VEHICLE STATUS:  NONE
                                   DEPLOYED TROOPS
AIRFIELD STATUS:                                               RRR CAPABILITY:  NONE
PAVE COND/CAP:   LCN 75 
BARRIERS:  2 BAK 12'S/2BAK  14'S
NAV AIDS:  ONLY R/W LIGHTS AND MAN T/W LIGHT
                      AVAIL. NO OTHER NAVAIDS IN OPERATION

FIRE FIGHTERS:                                                     EQUIPMENT/SUPPLIES:
CURRENT:  0                                                           VEHICLES:  5  P19'S 1 P13 1 P10 require
							        SOURCED (TRANSPORTATION)	
PROJECTED:  36                                                      AFFFF: NONE
                                                                                     AIR:  NONE

IMEACS:   We have a shortage of generators; suggest SAC bring 2 100kw's and 3 60kw's for back-up.

RECOMMENDATION:  If possible SAC maybe able to bring their own generators
because of our shortf all. 

COMMENDTS:  2 water buffalos will be needed.  Personnel will stay at Hotel
Moventick/Ramada, contract for hot breakfast and dinner, until the tent city

Document Page: First | Prev | Next | All | Image | This Release | Search