2-6. DRYING (*C'41UCIIOR ana, controo.
a. Since ventilation In drying areas Is usually very poor, sampling must
be performed to determine the air concentrations of the solvents when
personnel are working in these areas.
b. HDI in the PUP does not present a health hazard after the paint has
cured, unless exposed to heat sufficient for thermal decomposition of the
coating.
2-7. GRINDING AND SANDING (, ecoomilion).
a. Grinding or sanding painted surfaces can expose personnel to--
(1) hazardous concentrations of lead, zinc, copper, tin, or chromium
VI dusts from primers or paints, and
(2) noise and eye hazards associated with grinding.
b. There is no expected exposure from solvents or HDI.
2-8. GRINDING AND SANDING and conirot).
a. Atmospheric sampling of particulates should be conducted to determine
exposure levels. High efficiency air purifying respirators should be used
when grinding or sanding on painted equipment.
b. Noise readings should be taken during the operations to determine
exposure levels. Hearing protection should be worn and the area posted as
noise hazardous if noise levels exceed 85 dBA.
c. The potential for eye injuries exists during these operations and
protective eyewear should be worn. The area should be posted as an eye
hazardous area.
2-9. WELDING AND CUTTING Toxic gases, vapors, and metal fumes
are released when welding or cutting is performed on painted metal. Depending
on the types of coatings, these gases may include carbon monoxide, cyanides,
utting on CARC-coated metal
is prohibited because significant quantities of isocyanate may be released,
unless the coatings have been removed down to bare metal.
2-10. WELDING AND CUTTING (e,-aiiialion and controls). When welding or cuttin4
painted surfaces, sand or grind down to the bare metal an area 4 inches on
either side of where the heat is applied. If a painted surface is on the
other side of the weld spot, it must also be removed. In some operations,
local exhaust ventilation may be used to remove the fumes and gases.
2-4