26.Following a biological agent attack, all food except canned or otherwise
well nrotected food, should be thoroughly cooked mrior to consumption.
All food should be insnpcted to ensure -that it was adequately protected
while exnosed to the infectious cloud. Thorough cooking would make foods
safe for consumption unless they are contaminated with certain heat stable
toxins such as Stanhylococcal enterotoxin R or heat resistant qnnres such as
anthrax, Thorough cooking means that all marts have been heated close to
the boiling point for 15 minutes. All, foods determined to be Rafe must be
Protected a"ainst secondary contamination. These measures must be Practised
bv those who transnort, store, prenare and serve food, also those who eat
the food. When annlicable, consideration must be given to control measures
necessary to nrevent contamination of food by insects and rodents. Cans
should be decontaminated by chemical means, boiling or flaming, prior to
onening. After this the contents are safe to eat with or without heating.
"NCLASSTFTEN 16
UNCLASSTFIED
27. EmDerience from training and exercises has shown how difficult 4.t, 4--, to
maintain @atisfactn-v nprsonal and area field hygiene, particularly in
unfamiliar climates. Very strict measures are required concerning the
treatment of waste and Rewage as well as management- of latrines. The -isk
of a biological attack highlights the necessity o4 giving -raining i-ri these
measures in order to be nrenared @n -educe as much as nossible the R-ffects
of such an attack.
Document Page: First | Prev | Next | All | Image | This Release | Search
Document 109 f:/Week-36/BX003203/DETECTION OF MEDICAL DEFENSE AGAINST BIOLOGICAL MATERIALS/detection of medical defense against biological :1217960927452
Control Fields 17
File Room = sep96_declassified
File Cabinet = Week-36
Box ID = BX003203
Unit = OTSG
Parent Organization = HSC
Folder Title = DETECTION OF MEDICAL DEFENSE AGAINST BIOLOGICAL MATERIALS
Folder Seq # = 21
Subject = DETECTION OF MEDICAL DEFENSE AGAINST BIOLOGICAL
Document Seq # = 1
Document Date =
Scan Date =
Queued for Declassification = 01-JAN-1980
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 17-DEC-1996