Document Page: First | Prev | Next | All | Image | This Release | Search
File: 120596_aabxc_02.txt
IS COLLAPSED ON YOUR FACE, VERIFY SEAL WITH APPLICATOR DIPPED IN
N-AMYL ACETATE {BANANA OIL} {NSN 6810-00-123-7047} BY MOVING THE
APPLICATOR AROUND THE OUTLET VALVE AREA.
D. IF AN AIR LEAK OR BANANA SCENT IS DETECTED. DO THE
FOLLOWING:
(1) REMOVE AND DISCARD THE OUTLET VALVE.
( 2) CLOSELY INSPECT AND CLEAN AND INSERT A NEW OUTLET
VALVE.
(3) RETEST AND VALIDATE AS BEFORE {PARA 2C}.
(4) IN THE EVENT THAT THE REPLACEMENT VALVE STILL DOES NOT
PROVIDE A SEAL. TURN THE MASK IN FOR REPLACEMENT.
3. REQUEST WIDEST DISSEMINATION TO ALL SOLDIERS. CML OPS AND
MAINTENANCE PERSONNEL.
UNQUOTE
2. HQ SAC/SGAX POC [(b)(2)]
Document Page: First | Prev | Next | All | Image | This Release | Search