Document Page: First | Prev | Next | All | Image | This Release | Search
File: 120596_aabxc_01.txt
FROM: HQ SAC OFFUTT AFB NE
TO AIG 9462//SGAX//
ZEN EHRLING BERQUIST STRATHOSP AFB NE
UNCLASSIFIED
SUBJ: CB MASK M17, M24/25 SERIES MASK OUTLET VALVE
1. THE FOLLOWING CDR AMCCOM APG MD/AMSMC-MAR-EP MSG. 24ll00Z DEC 90
IS QUOTED IN PART FOR YOUR INFORMATION:
QUOTE
2. AS A RESULT OF THE ENVIRONMENTAL CONDITIONS EXPERIENCED IN SOUTH
WEST ASIA. THE FOLLOWING ADDITIONAL ACTIONS ARE REQUIRED TO ENSURE
CB MASK READINESS:
A. FOLLOW THE PMCS PROCEDURES OUTLINED IN THE APPROPRIATE TMS
CLOSELY AS IT PERTAINS TO OUTLET VALVE INSPECTION CLEANING AND
SERVICE. {REF TM 4240-279-20&P W/C2 PAGE 2-15 & 2-16 AND
TM 4240-280-20&P W/C2 PAGE 2-8}
B. USING A COTTON TIPPED APPLICATOR. {NSN 6515-00-303-8250}
MOISTENED IN ALCOHOL {NSN 6505-00-655-8366} THOROUGHLY CLEAN THE
OUTLET VALVE SURFACES AND VALVE SEAL OF ANY DUST, DIRT, OR SAND
C. WITH THE MASK PROPERLY FITTED ON THE FACE. INHALE AND
HOLD YOUR BREATH FOR 10-l5 SECONDS. AT THE SAME TIME WHILE THE MASK
[(b)(2)]
Document Page: First | Prev | Next | All | Image | This Release | Search