               ANNEX       to S3 After Action   @ieview, NOV 90 'lo !6 JAN



                    C. Recommended action:     The decon equ,-nment needs to be
               stored in a 1 1/2 ton covered   trailer. The contingency stock
               should be stored in a protected shelter, preferably a plastic
               l.ined bunker.

               4. Observation: Lack of two cycle oil tor @417 Sana'.o@.

                    A. Discussion: Despite reassurance from Brigade that two
               cycle oil was easily procurable, none ever surfaced through
               supply channels.

                    B. Lessons learned: Units had to rely on local purchase
               for two cycle oil. The local purchase amoun7@ was adequate, but
               slow to reach the units. 30 weight heavy duty oil is a substi-
               tute listed in the TM, but as I understand, tne MI-7 requires
               extensive service after build up of the residue (approximately 20
               hours). 30 weight oil could be used in an emergency.

                    C. Recommended action: Units should be allowed a 'basic
               load' of enough two cycle oil for 20 hours for training per
               quarter, and 100 hours for actual decon operations. This would
               amount to approximately 20 quarts per unit.

               S. Observation: Lack of plastic covering for bunkers.

                    A. Discussion: Bunkers were built promptly after units
               arrived. The best place for plastic is above the bunker, and
               under soil, which absorbs liquid contamination. The battalion
               received this plastic sheeting well after most bunkers were
               built.


                    B. Lessons learned: I recommended to all unit NBC NCOs to
               scrape the soil off the top of the bunker and put it back on top
               of the plastic sheeting. Very few took the recommendation, but
               the plastic was still secured on top of the bunkers. This re-
               sulted in numerous holes in the plastic.

                    C. Recommended action: Local purchase; of plastic betore
               leaving home station would facilitate the proper construction of
               bunkers. This is especially critical in a high chemical threat
               environment.


               6. Observation: Alternate power supply tor MSAI alarms in short
               supply.

                    A. Discussion: Due to short supply of BA351'[/Us, we made
               an attempt to obtain an alternate power supply. The alternates
               recommended by Brigade NBC were a cable which could be spliced
               directly into the M8AI and the M10AI power supply (which is
               recommended by the TM). We were already having difficulty ob-
               talining NBC related.supply, and Brigade was of no help I'n procur-
               ing these alternate power sources.

                    B. Lessons learned: We finally obtained one MlOAl power

Document Page: First | Prev | Next | All | Image | This Release | Search


Document 24 f:/Week-32/BX000545/3-43D ADA AAR OPERATION DESERT SHIELD/3rd bn patriot 43rd ada rgmt aar opn des shield:09229712012712
Control Fields 17
File Room = aug97_declassified
File Cabinet = Week-32
Box ID = BX000545
Unit = ARCENT
Parent Organization = CENTCOM
Folder Title = 3-43D ADA AAR OPERATION DESERT SHIELD
Folder Seq # = 36
Subject = 3RD BN PATRIOT 43RD ADA RGMT AAR OPN DES SHIELD
Document Seq # = 1
Document Date =
Scan Date = 11-AUG-1997
Queued for Declassification = 18-AUG-1997
Short Term Referral = 01-JAN-1980
Long Term Referral = 01-JAN-1980
Permanent Referral = 01-JAN-1980
Non-Health Related Document = 01-JAN-1980
Declassified = 22-SEP-1997